LS2-HMPHMP-D
D-CLASS LSF2-50 SureFlex® Jumper with interface types 4.3-10 PUSH PULL Male and 4.3-10 PUSH PULL Male, variable length
Features and benefits
- WARNING: DO NOT MATE WITH 4.1-9.5 DIN
Specifications
Product classification
| Product Type | Wireless transmission cable assembly |
| Product Series | LSF2-50 |
General specifications
| Body Style, Connector A | Straight |
| Body Style, Connector B | Straight |
| Interface, Connector A | 4.3-10 Male |
| Interface, Connector B | 4.3-10 Male |
| Specification Sheet Revision Level | A |
| Variable Length | For custom lengths, contact your local ANDREW representative |
Dimensions
| Nominal Size | 3/8 in |
Logo image
| Click on image to enlarge. |
Electrical specifications
| 3rd Order IMD Dynamic | -119 dBm |
| 3rd Order IMD Dynamic Test Method | Two +43 dBm carriers per IEC 62037 |
Return loss/vswr
| Frequency band | Vswr | Return loss (db) |
| 698–970 MHz | 1.065 | 30.04 |
| 1700–2200 MHz | 1.065 | 30.04 |
| 2200–2700 MHz | 1.083 | 27.99 |
| 3400–3800 MHz | 1.222 | 20.01 |
| 4000–6000 MHz | 1.222 | 20.01 |
Jumper assembly sample label
| Click on image to enlarge. |
Environmental specifications
| Immersion Test Method | Meets IEC 60529:2001, IP68 in mated condition |
Product classification
| Product Type | Wireless transmission cable assembly |
| Product Series | LSF2-50 |
General specifications
| Body Style, Connector A | Straight |
| Body Style, Connector B | Straight |
| Interface, Connector A | 4.3-10 Male |
| Interface, Connector B | 4.3-10 Male |
| Specification Sheet Revision Level | A |
| Variable Length | For custom lengths, contact your local ANDREW representative |
Dimensions
| Nominal Size | 3/8 in |
Electrical specifications
| 3rd Order IMD Dynamic | -119 dBm |
| 3rd Order IMD Dynamic Test Method | Two +43 dBm carriers per IEC 62037 |
Return loss/vswr
| Frequency Band | VSWR | Return Loss (dB) |
| 698–970 MHz | 1.065 | 30.04 |
| 1700–2200 MHz | 1.065 | 30.04 |
| 2200–2700 MHz | 1.083 | 27.99 |
| 3400–3800 MHz | 1.222 | 20.01 |
| 4000–6000 MHz | 1.222 | 20.01 |
Environmental specifications
| Immersion Test Method | Meets IEC 60529:2001, IP68 in mated condition |
| Click on image to enlarge. |
| Click on image to enlarge. |